Trane Air Conditioner 4ttx6048 User Manual

Split System  
Cooling  
Product Data  
XL16i  
4TTX6024, 036, 048 & 060E  
2, 3, 4 & 5 Tons  
PUB. NO. 22-1752-10  
Contents  
features and Benefits  
2
General Data  
4
4
4
5
5
Product Specifications  
A-weighted Sound Power Level [dB(A)]  
Accessory Description and Usage  
AHRI Standard Capacity Rating Conditions  
model Nomenclature  
Electrical Data  
6
7
8
9
Dimensions  
mechanical Specifications  
22-1752-10  
3
General  
Data  
Product Specifications  
Model No. 1  
4TTX6024E1  
4TTX6036E1  
4TTX6048E1  
4TTX6060E1  
Electrical Data V/Ph/Hz 2  
Min Cir Ampacity  
Max Fuse Size (Amps)  
230/1/60  
14  
20  
230/1/60  
22  
35  
230/1/60  
29  
50  
230/1/60  
39  
60  
Compressor  
CLIMATUFF® - SCROLL  
CLIMATUFF® - SCROLL  
CLIMATUFF® - SCROLL  
CLIMATUFF® - SCROLL  
RL AMPS - LR AMPS  
Outdoor Fan FL Amps  
Fan HP  
10.3 - 52  
0.74  
1/8  
16.7 - 82  
0.74  
1/8  
21.2 - 104  
2.80  
1/3  
28.8 - 152.9  
2.80  
1/3  
Fan Dia (inches)  
27.6  
27.6  
27.6  
27.6  
Coil  
Spine Fin™  
9/13-LB/OZ  
5/8  
Spine Fin™  
9/13-LB/OZ  
3/4  
Spine Fin™  
12/9-LB/OZ  
7/8  
Spine Fin™  
12/9-LB/OZ  
1-1/8  
Refrigerant R-410A  
Line Size - (in.) O.D. Gas 3  
Line Size - (in.) O.D. Liquid 3  
3/8  
3/8  
3/8  
3/8  
Dimensions H x W x D (Crated) 53.4 x 35.1 x 38.7  
57.4 x 35.1 x 38.7  
57.4 x 35.1 x 38.7  
57.4 x 35.1 x 38.7  
Weight - Shipping  
Weight - Net  
309  
261  
316  
266  
328  
291  
332  
295  
Start Components  
Sound Enclosure  
Compressor Sump Heat  
NO  
NO  
NO  
NO  
NO  
NO  
NO  
NO  
NO  
NO  
NO  
NO  
Optional Accessories: 4  
Rubber Isolator Kit  
Snow Leg - Base & Cap 4" High  
Snow Leg - 4" Extension  
Hard Start Kit Scroll  
BAYISLT101  
BAYLEGS002  
BAYLEGS003  
BAYKSKT260  
BAYCCHT301  
BAYECMT023  
BAYVDTA003  
BAYCAKT001  
TAYREFLN9*  
BAYISLT101  
BAYLEGS002  
BAYLEGS003  
BAYKSKT260  
BAYCCHT301  
BAYECMT004  
BAYVDTA004  
BAYCAKT001  
TAYREFLN7*  
BAYISLT101  
BAYLEGS002  
BAYLEGS003  
BAYKSKT260  
BAYCCHT301  
BAYECMT004  
BAYVDTA004  
BAYCAKT001  
TAYREFLN3*  
BAYISLT101  
BAYLEGS002  
BAYLEGS003  
BAYKSKT260  
BAYCCHT301  
BAYECMT004  
BAYVDTA004  
BAYCAKT001  
TAYREFLN4*  
Crankcase Heater Kit  
Extreme Condition Mounting Kit  
Vertical Discharge Air Kit Base 4  
Auto Charge Solenoid Kit  
Refrigerant Lineset 5  
1 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240.  
2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.  
3 Standard line lengths - 60'. Standard lift - 25' Suction and Liquid line.  
For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0. (denotes latest revision)  
4 For accessory description and usage, see page 5.  
5 * = 15, 20, 25, 30, 40 and 50 foot lineset available.  
A-weighted Sound Power Level [dB(A)]  
SOUND POWER  
LEVEL [dB(A)]  
A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB - [dB(A)]  
MODEL  
63  
125  
250  
500  
1000  
2000  
4000  
8000  
4TTX6024E  
4TTX6036E  
4TTX6048E  
4TTX6060E  
72  
72  
73  
74  
43.7  
52.6  
54.3  
62.4  
60.4  
57  
54.1  
46.6  
38  
50.4  
50.4  
53.8  
56.8  
58.9  
57.8  
60.4  
63.1  
66  
59.8  
63  
57.2  
57.4  
57.7  
55.2  
53.6  
58.4  
49.2  
47.4  
51.7  
44.2  
42.2  
65.7  
Note: Rated in accordance with AHRI Standard 270-2008.  
4
22-1752-10  
General  
Data  
accessory Description and Usage  
ahRi Standard Capacity Rating Conditions  
ahRi STaNDaRD 210/240 RaTiNG CONDiTiONS —  
(A) Cooling 80°F DB, 67°F WB air entering indoor coil,  
95°F DB air entering outdoor coil.  
(B) High Temperature Heating 47°F DB, 43°F WB air entering  
outdoor coil, 70°F DB air entering indoor coil.  
(C) Low Temperature Heating 17°F DB, 15°F WB air entering  
outdoor coil, 70°F DB air entering indoor coil.  
Rubber isolators — 5 rubber donuts to isolate condens-  
ing unit from mounting frame or pad. Use on any application  
where sound transmission needs to be minimized.  
Extreme Conditions mounting kit — Bracket kits to secure-  
ly mount condensing unit to a frame or pad without removing  
any panels. Use in areas with high winds, or on commercial  
rooftops, etc.  
(D) Rated indoor airflow for heating is the same as for cooling.  
Low ambient Cooling — For low ambient cooling below 55°  
see Application Guide APP-APG013-EN.  
ahRi STaNDaRD 270 RaTiNG CONDiTiONS — (Noise  
rating numbers are determined with the unit in cooling opera-  
tion.) Standard Noise Rating number is at 95°F outdoor air.  
22-1752-10  
5
Model  
Nomenclature  
T
U
D
2
B
0
8
0
A
C
V
3
2
A
A
4 T  
T
X
6
0
3
6
E
1
0
0
0 A  
A
Gas Furnaces  
Outdoor Units  
Refrigerant Type  
4 = R-410A  
TRANE  
Product Type  
W = Split Heat Pump  
T = Split Cooling  
Product Family  
Z = Leadership – Two Stage  
X = Leadership  
R = Replacement/Retail  
M or B = Basic  
A = Light Commercial  
Family SEER  
3 = 13  
4 = 14  
5 = 15  
6 = 16  
8 = 18  
9 = 19  
0 = 20  
Split System Connections 1-6 Tons  
0 = Brazed  
Nominal Capacity in 000s of BTUs  
Major Design Modifications  
Power Supply  
1 = 200-230/1/60 or 208-230/1/60  
3 = 200-230/3/60  
4 = 460/3/60  
Secondary Function  
Minor Design Modifications  
Unit Parts Identifier  
4
T
X
C
B
0
0
1
C
C
3
H
C
A
A
4
T
E
E
3
F
3
6
A
1
0
0
0
A
A
Coils –  
Air Handlers –  
Residential  
Residential  
RefrigerantType  
Refrigerant Type  
4 - R410A  
4 = R-410A  
Product Family  
T-Premium  
(HeatPumporConvertibleCoil)  
Application  
TE = Fully Convertible  
TG = Semi Convertible  
TF = Front Return  
Coil Design  
X - Direct Expansion Evaporator Coil  
Product Family  
C - Cased A Coil  
Product Family  
E = Leadership – Variable Speed  
P = Leadership  
A - Uncased A Coil  
F - Cased Horizontal Flat Coil  
C = Replacement/Retail  
B = Basic  
CoilWidth(Cased/Uncased)  
A - 14.5" / 13.3"  
B - 17.5" / 16.3"  
C - 21.0" / 19.8"  
D - 24.5" / 23.3"  
H - 10.5"  
Flow Control  
0 = No Flow Control  
3 = Nonbleed TXV  
RefrigerantLineCoupling  
Feature Identifier  
0 = Standard Unit  
F = Air-Tite™  
0 - Brazed  
ModelNumberDistinguisher  
MajorDesignChange  
Nominal Capacity in 1000’s (BTUH)  
Major Design Change  
Efficiency  
C - Standard  
Power Supply  
1 = Single Phase  
S - Hi Efficiency (Derived from 10 SEER products)  
RefrigerantControl  
Electrical Connection  
0 = Pig Tails  
B = Circuit Breaker  
D = Pull Disconnect  
3 - TXV - Non-Bleed  
Coil Circuitry  
H - Heat Pump  
AirflowConfiguration  
A - Upflow Only  
Future Option – Factory Installed Heater Nominal KW Value  
Minor Design Modifications  
U - Upflow / Downflow  
H - Horizontal Only  
Unit Parts Identifier  
C - Convertible - Upflow, Downflow, Left or Right Airflow  
NOTE: There will be a phase-in of new model numbers for new  
air handlers over next 2 years.  
MinorDesignChange  
UnitPartsIdentifier  
6
22-1752-10  
Electrical  
Data  
Schematic Diagrams  
(SEE LEGEND)  
4TTX6024E, 036E  
Printed from D156630P02 Rev 00  
22-1752-10  
7
Electrical  
Data  
Schematic Diagrams  
(SEE LEGEND)  
4TTX6048E, 060E  
8
22-1752-10  
Electrical  
Data  
Schematic Diagrams  
LEGEND  
22-1752-10  
9
Dimensions  
4TTX6 Outline Drawing  
Note: all dimensions are in mm (inches).  
mODELS  
BaSE  
a
B
C
D
E
f
G
h
J
k
4TTX6024E  
4TTX6036E  
4TTX6048E  
4TTX6060E  
4
4
4
4
1267 (49-7/8) 946 (37-1/4) 870 (34-1/4)  
1369 (53-7/8) 946 (37-1/4) 870 (34-1/4)  
1369 (53-7/8) 946 (37-1/4) 870 (34-1/4)  
5/8  
3/4  
7/8  
3/8  
3/8  
3/8  
152 (6)  
152 (6)  
152 (6)  
152 (6)  
98 (3-7/8) 219 (8-5/8) 86 (3-3/8)  
730 (28-3/4)  
98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 1035 (40-3/4)  
98 (3-7/8) 219 (8-5/8) 86 (3-3/8)  
98 (3-7/8) 219 (8-5/8) 86 (3-3/8)  
730 (28-3/4)  
730 (28-3/4)  
1369 (53-7/8) 946 (37-1/4) 870 (34-1/4) 1-1/8 3/8  
From Dwg. D152635 Rev. 16  
22-1752-10  
10  
Mechanical  
Specifications  
General  
Condenser Coil  
The 4TTX6 is fully charged from the fac-  
tory for matched indoor section and up  
to 15 feet of piping. This unit is designed  
to operate at outdoor ambient tempera-  
tures as high as 115°F. Cooling capaci-  
ties are matched with a wide selection  
of air handlers and furnace coils that are  
AHRI certified. The unit shall be certi-  
fied to UL 1995. Exterior is designed for  
outdoor application.  
The outdoor coil provides low airflow  
resistance and efficient heat transfer.  
The coil is protected on all four sides by  
louvered panels.  
Low ambient Cooling  
As manufactured, this unit has a cool-  
ing capability to 55°F. For low ambient  
cooling below 55° see Application Guide  
APP-APG013-EN.  
Casing  
Unit casing is constructed of heavy  
gauge, G60 galvanized steel and  
painted with a weather-resistant powder  
paint on all louvers and panels. Cor-  
rosion and weatherproof CMBP-G30  
DuraTuff™ base.  
Refrigerant Controls  
Refrigeration system controls include  
condenser fan, compressor contactor  
and high pressure switch. High and low  
pressure controls are inherent to the  
compressor. A factory installed liquid line  
drier is standard.  
Compressor  
The Climatuff® 2-stage compressor  
features internal over temperature and  
pressure protection and hermetic motor.  
Other features include: roto lock suction  
and discharge refrigerant connections,  
centrifugal oil pump and modular plugs  
for electrical connections.  
22-1752-10  
11  
10/10  
Trane  
Trane has a policy of continuous product and product data improvement and it reserves the right to change  
design and specifications without notice.  

Lifebreath 200max Rx User Manual
Samsung As18j User Manual
Samsung Digital Laser Mfp Scx 4116 User Manual
Sears 2007121 User Manual
Sharp Af Q120px User Manual
Soleus Air Air Conditioner Gm Ttw 12esez User Manual
Subaru Automobile Parts Eh36 User Manual
Teledyne 730 Bubbler User Manual
Toshiba Workgroup17 User Manual
Xerox All In One Printer Workcenter M20i User Manual